Table 6-4.--Power Supply, Controls and Indicators
FUNCTION
POSITION/INDICATION
DESIGNATION
Conditions AMPS meter to measure charger current.
Up--charger current.
CHARGER
Down--charger current not available to
CURRENT
Switch
AMPS meter.
Conditions AMPS meter to read battery curreny.
BATTERY
Up--battery current.
Down--battery current not available to
CURRENT
AMPS meter.
Switch
Allows changing of position of BATTERY CURRENT
CHANGE (up)--no AMPS meter indi-
CHANGE/
READ
cation.
and CHARGER CURRENT positions.
READ (down)--AMPS meter indication.
Switch
When changing the positions of the CHARGER
CURRENT and BATTERY CURRENT
switches, the CHANGE/READ switch must be
set to the CHANGE position to prevent the switch
contacts from arcing,
Indicates charger, battery or load current depending on
0--30 amperes.
AMPS Meter
switch conditions.
Up--at power applied to power supply.
Energizes or de-energizes power supply via ac power
CHARGER ON
input.
Switch
Down--at power removed from power
supply.
On--fuse failed.
Protects power supply and switchboard from damage
+48 10 AMP
Off--normal.
due to excessive current in (he 51.6 volt supply circuit.
Fuse
On-fuse failed.
Protects power supply and primary ac power source from
LINE 10 AMP
Off--normal.
damage due to excessive line current.
Fuses
0--100 volts.
Indicates battery or charger voltage depending on
VOLTS Meter
position of BATTERY/CHARGER switch.
BATTERY (up)--ship's battery voltage.
Conditions VOLT meter to read battery voltage or power
BATTERY/
CHARGER (down)--power supply volt-
supply voltage.
CHARGER
age.
Switch
EQUALIZE (up)--maximum charging
Selects float charge or quick charge for ship's battery.
EQUALIZE/
current.
FLOAT Switch
FLOAT (down)--charging current deter-
mined by VOLTAGE ADJUST control.
Up--power supply connected to ship's
Connects power supply output to ship's battery.
BATTERY CON-
battery.
NECT Switch
Down--power supply disconnected from
ship's battery.
Set and locked for 51.6 volts dc at factory,
Varies output voltage of power supply.
VOLTAGE AD-
JUST CONTROL
6-25