Table 6-10.--XY Universal Switch Test Set Operation Procedures--Continued
LAMP
FUNCTION
Lights to indicate that break contacts of RLS springs are
RELEASE (White)
closed.
Goes out to indicate that break contacts of RLS springs
are open.
Lights to indicate that make contacts of RLS springs are
RELEASE (Red)
closed.
Goes out to indicate that make contacts of RLS springs
are open.
Lights to indicate that break contacts of X-Y overflow
OVERFLOW (White)
springs are closed.
Goes out to indicate that break contacts of X-Y overflow
springs are open.
Lights to indicate that make contacts of X-Y overflow
OVERFLOW (Red)
springs are closed,
Goes out to indicate that make contacts of X-Y overflow
springs are open,
Lights to indicate that stepping speed of XY Universal
SPEED 25-32 (Green)
Switch under tests is within range of 25-32 steps per
second.
Goes out to indicate that stepping speed of XY Universal
Switch is outside range of 25 to 32 steps per second.
Lights once and goes out to indicate that stepping speed
of XY Universal Switch is below 25 steps per second,
SPEED 32-45 (Green)
Lights to indicate that stepping speed of Xf Universal
Switch is above 32 but below 45 steps per second,
Goes out to indicate that stepping speed of XY Universal
Switch is outside range of 32 to 45 steps per second.
Lights once and goes out to indicate that stepping speed
of XY Universal Switch is below 32 steps per second.
6-55